The basic principles of circuit breaker operation
(Prinsip asas operasi pemutus litar-CB)

A circuit breaker serves two purposes: 

(i) Switching on and off during normal operation for maintenance etc. 
(ii) Switching during abnormal conditions- short circuits, earthing etc. to protect the associated equipment.

Pemutus litar berfungsi dua tujuan:
(i) Menghidupkan dan mematikan semasa operasi normal untuk penyelenggaraan dll.
(ii) Menghidupkan semasa keadaan tidak normal - litar pintas, pembumian dll untuk melindungi peralatan yang berkaitan.

A circuit breaker essentially consists of fixed and moving contacts, called electrodes. Under normal operating conditions, these contacts remain closed and will not open automatically until and unless the system becomes faulty. The contacts can be opened manually or by remote control whenever desired. When a fault occurs on any part of the system, the trip coils of the circuit breaker get energized and the moving contacts are pulled apart by some mechanism, thus opening the circuit.

Pemutus litar (CB) pada dasarnya terdiri daripada contact tetap dan bergerak, disebut elektrod. Di bawah keadaan operasi normal, contact ini sentiasa ditutup dan tidak akan dibuka secara automatik sehingga dan melainkan sistemnya rosak. Contact boleh dibuka secara manual atau dengan kawalan jauh apabila dikehendaki. Apabila berlaku kerosakan pada mana-mana bahagian sistem, gegelung 'trip' CB semakin bertenaga dan contact bergerak ditarik terpisah oleh beberapa mekanisme, dengan itu membuka litar.


When the contacts of a circuit breaker are separated under fault conditions, an arc is struck between them. The current is thus able to continue until the discharge cease. The production of arc not only delays the current interruption process but it also generates enormous heat which may cause damage to the system or to the circuit breaker itself. Therefore, the main problem in a circuit breaker is to extinguish the arc within the shortest possible time so that heat generated by it may not reach a dangerous value.


Apabila contact CB dipisahkan di bawah keadaan 'fault,  arc terhasil di antara mereka. Oleh itu, arus ini dapat diteruskan sehingga nyahcas nya berhenti. Pengeluaran arka bukan sahaja menangguhkan current interruption process tetapi juga menghasilkan haba yang sangat besar yang boleh menyebabkan kerosakan pada sistem atau CB itu sendiri. Oleh itu, masalah utama dalam CB adalah memadamkan arka dalam masa yang sesingkat mungkin sehingga haba yang dihasilkan olehnya mungkin tidak mencapai nilai berbahaya.